Hot Water Calibration Hot Water Calibration

Hot Water Calibration

Introduction

If you’re noticing the amount of hot water dispensed does not match the amount selected, you can recalibrate your machine for better results. The process is easy—you’ll use a scale once to teach the machine the correct amount, then you’ll be good to go!

 

What You'll Need:

For this process, all you need is water for your Series 1 and a reliable scale.

 


Calibration Steps

Step 1: Weigh the Water

Place an empty cup on a zeroed scale under the grouphead. Then, press the hot water button on top of your machine (the piano button on the right side with the water droplet).
 

Write down:

  • Your target volume (e.g., 6 oz or 200 ml)
  • The actual weight you got

 

Step 2: Calculate the Correction

Formula: Actual volume ÷ Target Volume

Examples:

  • Target 7 oz (207 ml), got 180 g → correction +13%
  • Target 200 ml, got 180 g → correction +10%

 

Step 3: Enter the Correction

  • Go to Settings → Customization → Nerdy Settings -> Scroll to WATER OFFSETS
  • Adjust the percentage multiplier from 0 to the number you just calculated

 